GS5015 Battery Rated Capacity [kWh]: 5015.96 Charging C-rate: ≤0.5CP Discharging C-rate: ≤0.5CP Maximum Charging/Discharging Power [kW]: 2500 Dimensions [mm] (L*W*H): 6058*2438*2896 Weight [T]: Approx.42.5
The GS5015 Containerized Liquid-Cooled Utility ESS primarily consists of 51 24Ah liquid-cooled battery PACKs, a control box, a main control panel, a liquid cooling unit, a liquid cooling pipeline system, a BMS (Battery Management System), an auxiliary power distribution system, a fire suppression system, and so on. The total energy storage capacity is 5015.96 kWh, utilizing 214Ah Li-ion iron Phosphate (LFP) battery cells. A single PACK is configured as 1P25S. Each battery cluster consists of 30 battery PACKs, forming a 3P30S structure. Each battery cluster's power distribution is equipped with one control box. The DC side supports multiple parallel branch circuits converging into a centralized DC cabinet with a main control. The temperature control system utilizes a liquid cooling unit for battery temperature control and a liquid cooling pipeline system for heat exchange. The thermal management system is equipped with fresh air intake and exhaust + water fire suppression solution. The overall container utilizes a non-walk-in external maintenance design.
The GS5015 containerized Liquid-Cooled Utility Energy Storage System primarily consists of 314Ah liquid-cooled battery PACKs, a control box, a main control panel, a liquid cooling unit, a liquid cooling pipeline system, a BMS (Battery Management System), a fire protection system, auxiliary power distribution, and more.
Key Features
ed production supports cost-effective and efficient deployment on-site, effectively reducing construction workload; on-site installation and commissioning efficiency improved by 50%, lowering project costs.
Model: GS5015
| Category | Name | Parameter | Remarks |
| Battery Parameters | Battery Rated Capacity (KWh) | 5015.96 | |
| Cell Type | LFP | ||
| Cell Rated Voltage | 3.2V | ||
| Voltage Range (VDC) | 1164.8 - 1497.6 | ||
| Rated Current (A) | 3220 | ||
| Discharging Rate | 0.5C/1C | ||
| Maximum Continuous Charging/Power (kW) | 1875 | 2 units of 1250kW PCS | |
| Maximum Continuous Discharging/Power (kW) | 2500 | ||
| Operating Temperature Range (°C) | 0 - 45 | ||
| Recommended Temperature Range (°C) | 15 - 35 | ||
| Thermal Management | Cooling Method | Liquid Cooling | No Propylene Glycol |
| Air Change Method | Air Inlet & Air Outlet | ||
| Anti-Corrosion Grade | C4 | ||
| System Parameters | Fire Suppression System Grade | Class C | |
| Protection Level | IP55 for Battery compartment; IP54 for Control Room | ||
| Operating Temperature Range (°C) | -20 - +35 (≤6 month), -20 - +45 (≤1 month) | Derating when >40℃ | |
| Storage Temperature Range (°C) | -20 - +35 (≤6 month), -20 - +45 (≤1 month) | Derating when >40℃, SOC: 40% - 50% | |
| Operating Humidity Range | 0 - 95% | No condensation | |
| System Composition | Maximum 2 Enclosures + 2 damages per day | ||
| System Communication Protocol | Modbus TCP/IP | ||
| Working Condition | On-Grid / Off-Grid / Back-Up | ||
| System Power Conversion Interface | Single - Point | ||
| External System Communication Protocol | Modbus TCP/IP, IEC61850, Modbus RTU | Derating when >2000m | |
| Dimension (L*W*H) | 20ft/40ft | ||
| Equipment (total) (L*W*H) | 6058*2438*2896 | ||
| Weight | 24000 kg | ||
| Certification | IEC 62619, IEC62040, IEC61000, IEC62477, IEC60664, UN38.3, UL1973, VDE4110, VDE4120, UN38.3, UN3480 |